STANDARDS : TSE 9760 oHD 21.5 S3 oVDE 0281-5 oIEC 60227 oBS 6500
APPLICATION :
In dry, damp and wet locations as flexible connecting cables for light mechanical stresses. It's used at ambient
temperatures up to 70 ° C kitchen and hand tools etc.
CONSTRUCTION :
1. Finely stranded copper conductor
2. PVC Insulation
3. PVC Outer sheath
TECHNICAL DATA :
Max. Operation Temperature : 70 C
Max. Short Circuit Temperature : 160 C
Rated Voltage (Uo/U) : 300/300 V (H03VV-F)
AC Test Voltage : 2 kV
APPLICATION :
Suitable in dry locations for connections of portable electrical appliances submitted to low voltage, like radio sets and lighting fittings but not for heating devices.
CONSTRUCTION :
1. Finely stranded copper conductor
3. PVC Outer sheath
TECHNICAL DATA :
Max. Operation Temperature : 70C
Max. Short Circuit Temperature : 160C
Rated Voltage (Uo/U) : 300/ 300V (H03VVH2-F)
300/500 V (H05VVH2-F)
AC Test Voltage : 2 kV
STANDARDS : TSE 9758 HD 21.3 S3 VDE 0281-3 IEC 60227 BS 6004
APPLICATION :
In dry locations in conduit on and under plaster. Not approved for direct installation in plaster in switching and distribution stations, for connection parts according to TS 9758
CONSTRUCTION :
1. Solid or stranded copper conductor
2. PVC Insulation
TECHNICAL DATA :
Max. Operation Temperature : 70 C
Max. Short Circuit Temperature : 160 C
Rated Voltage (Uo/U) : 300/500 V (H05V-U)
450/750 V (H07V-U/R)
AC Test Voltage : 2 -2,5 kV
STANDARDS : TSE 9758 HD 21.3 S3 VDE 0281-3 IEC 60227 BS 6004
APPLICATION :
In moving places and used for instrument cabling and equipment connection, in the pipe, under or on the plaster.
CONSTRUCTION :
1. Finely stranded copper conductor
2. PVC Insulation
TECHNICAL DATA :
Max. Operation Temperature : 70 C
Max. Short Circuit Temperature : 160 C
Rated Voltage (Uo/U) : 300/500 V (H05V-K)
450/750 V (H07V-K)
AC Test Voltage : 2 - 2,5 kV
STANDARDS : TSE 9759 - HD 21.4 S2 - VDE 0250 IEC 60227 - BS 6004
APPLICATION :
In dry, damp and wet locations on premises and in store rooms with fire and explosion hazard also out doors but not buried in the ground
CONSTRUCTION
1. Solid or stranded copper conductor
2. PVC Insulation
3. Filler
4. PVC outer sheath
TECHNICAL DATA
Max.Operation Temperature : 70° C
Max. Short Circuit Temperature : 160° C
Rated Voltage (Uo/U) : 300 / 500 Volt
AC Test Voltage : 2 kV
STANDARDS : TS IEC 60502-1 VDE 0276 IEC 60502 BS 6346
APPLICATION :
Preferably for installation indoors, in cable ducts and in industrial plants or switching stations, underground installation with
additional protection where mechanical damage must be unexpected
CONSTRUCTION :
1. Solid or stranded copper conductor
2. PVC Insulation
3. Filler
4. PVC outer sheath
TECHNICAL DATA :
Max. Operation Temperature : 70 C
Max. Short Circuit Temperature : 160 C
Rated Voltage (Uo/U) : 0,6/1 kV
AC Test Voltage : 3,5 kV
STANDARDS : TS IEC 60502-1 o VDE 0276 o IEC 60502 o BS 7889/7655
APPLICATION :
They are used as power distribution cables in power stations, in indoors and underground where there is no mechanical stress
CONSTRUCTION :
1. Solid or stranded copper conductor
2. XLPE (cross linked Polyethylene) insulation
3. Filler
4. PVC Outer sheath
TECHNICAL DATA :
Max. Operation Temperature : 90 C
Max. Short Circuit Temperature : 250 C
Rated Voltage (Uo/U) : 0,6/1 kV
AC Test Voltage : 3,5 kV
STANDARDS : VDE 0250/201 IEC 332-1
APPLICATION :
In on or under plaster including installations in bathrooms and shower compartment in dwellings and hotels. Without plaster covering in cavities of ceilings and walls of non flammable materials. Not permitted in wooden houses or buildings used for agricultural purposes, or in adjacent section of buildings not separated from them by fireproof walls.
CONSTRUCTION :
1. Finely stranded or solid copper conductor
2. PVC Insulation
3. PVC Outer sheath
TECHNICAL DATA :
Max. Operation Temperature : 70 C
Max. Short Circuit Temperature : 160 C
Rated Voltage (Uo/U) : 380V
AC Test Voltage : 2kV
STANDARDS : TS HD 21.12 S1 o VDE 0281 o BS 6141
APPLICATION :
For installations in domestic environment, kitchen, office and household appliances, also in humid conditions,
as well as connections subject to medium mechanical stress. Also, they can be used for kitchen or heating
appliances, if cable is not in direct touch with hot surfaces nor exposed to thermal irradiation.
CONSTRUCTION :
1. Finely stranded copper conductor
2. PVC Insulation
3. PVC Outer sheath
TECHNICAL DATA :
Max. Operation Temperature : 90 C
Max. Short Circuit Temperature : 160 C
Rated Voltage (Uo/U) : 300/300 V (H03V2V2-F)
300/500 V (H05V2V2-F)
AC Test Voltage : 2 kV
STANDARDS : TS HD 21.12 S1 oVDE 0281 o BS 6141
APPLICATION :
Suitable in dry locations for connections of portable electrical appliances submitted to low voltage, like radio sets and lighting fittings but not for heating devices.
CONSTRUCTION :
1. Finely stranded copper conductor
2. PVC Insulation
3. PVC Outer sheath
TECHNICAL DATA :
Max. Operation Temperature : 90 C
Max. Short Circuit Temperature : 160 C
Rated Voltage (Uo/U) : 300/300 V (H03V2V2H2-F)
300/500 V (H05V2V2H2-F)
AC Test Voltage : 2kV
STANDARDS : TSE 9760 HD 21.5 S3 VDE 0281 IEC 60227 BS 6500
APPLICATION :
Suitable in dry locations for connections of portable electrical appliances submitted to weak strength, like radio sets and lighting fittings but not for heating devices
CONSTRUCTION :
1. Finely stranded copper conductor
2. PVC Insulation
TECHNICAL DATA :
Max. Operation Temperature : 70 C
Max. Short Circuit Temperature : 160 C
Rated Voltage (Uo/U) : 300/300 V (H03VH-H)
300/500 V (H05V-K)
AC Test Voltage : 2 kV