All the detailed technical specification regarding with the various cables that are being produced under our own brand name as "ZAFER KABLO" can be found  in this section.

You are mostly welcomed to search for the data belongs to your inquiry of the cable type.You can also either match the data  with your own data inquiries or forward us your inquiry including all your specific technical details via our contact section.

All the thecnical specification  that has been presented  by us   not only includes the minimum values that the standarts stipulates but also involves the average degrees in order to meet all the detailed inquiries that our goodly clients are in need of.

The cables that are the products of careful work are put into service of our  beloved visitors..

Everybody Needs Professional Partner
STANDARDS : TSE 9758 HD 21.3 S3 VDE 0281-3 IEC 60227 BS 6004


APPLICATION :
In dry locations in conduit on and under plaster. Not approved for direct installation in plaster in switching and distribution stations, for connection parts according to TS 9758


CONSTRUCTION :
1. Solid or stranded copper conductor
2. PVC Insulation


TECHNICAL DATA :
Max. Operation Temperature : 70 C
Max. Short Circuit Temperature : 160 C
Rated Voltage (Uo/U) : 300/500 V (H05V-U)
450/750 V (H07V-U/R)
AC Test Voltage : 2 -2,5 kV
H05V-U H07V-U H07V-R (NYA)
Harmonized Cables and Insulation Cables
STANDARDS : TSE 9758 HD 21.3 S3 VDE 0281-3 IEC 60227 BS 6004


APPLICATION :
In moving places and used for instrument cabling and equipment connection, in the pipe, under or on the plaster.


CONSTRUCTION :
1. Finely stranded copper conductor
2. PVC Insulation


TECHNICAL DATA :
Max. Operation Temperature : 70 C
Max. Short Circuit Temperature : 160 C
Rated Voltage (Uo/U) : 300/500 V (H05V-K)
450/750 V (H07V-K)
AC Test Voltage : 2 - 2,5 kV
H05V-K / H07V-K (NYAF)
Harmonized Cables and Installation Cables
STANDARDS   : TSE 9759 - HD 21.4 S2 - VDE 0250  IEC 60227 - BS 6004


APPLICATION :
In dry, damp and wet locations on premises and in store rooms with fire and explosion hazard also out doors but not buried in the ground


CONSTRUCTION 
1. Solid or stranded copper conductor
2. PVC Insulation
3. Filler 
4. PVC outer sheath 


TECHNICAL DATA
Max.Operation Temperature    : 70° C
Max. Short Circuit Temperature : 160° C
Rated Voltage (Uo/U) : 300 / 500 Volt
AC Test Voltage : 2 kV
NVV (NYM)
300/500 V PVC Insulated Low Voltage Cables
STANDARDS : TS IEC 60502-1 VDE 0276 IEC 60502 BS 6346


APPLICATION :
Preferably for installation indoors, in cable ducts and in industrial plants or switching stations, underground installation with
additional protection where mechanical damage must be unexpected


CONSTRUCTION :
1. Solid or stranded copper conductor
2. PVC Insulation
3. Filler
4. PVC outer sheath


TECHNICAL DATA :
Max. Operation Temperature : 70 C
Max. Short Circuit Temperature : 160 C
Rated Voltage (Uo/U) : 0,6/1 kV
AC Test Voltage : 3,5 kV
NYY (YVV)
0,6/1 kV PVC Insulated Low Voltage Cables
STANDARDS : TS IEC 60502-1 o VDE 0276 o IEC 60502 o BS 7889/7655


APPLICATION :
They are used as power distribution cables in power stations, in indoors and underground where there is no mechanical stress


CONSTRUCTION :
1. Solid or stranded copper conductor
2. XLPE (cross linked Polyethylene) insulation
3. Filler
4. PVC Outer sheath


TECHNICAL DATA :
Max. Operation Temperature : 90 C
Max. Short Circuit Temperature : 250 C
Rated Voltage (Uo/U) : 0,6/1 kV
AC Test Voltage : 3,5 kV
N2XY ( YXV )
0,6/ 1Kv XLPE Insulated Low Voltage electric Cable
STANDARDS : VDE 0250/201 IEC 332-1


APPLICATION :
In on or under plaster including installations in bathrooms and shower compartment in dwellings and hotels. Without plaster covering in cavities of ceilings and walls of non flammable materials. Not permitted in wooden houses or buildings used for agricultural purposes, or in adjacent section of buildings not separated from them by fireproof walls.


CONSTRUCTION :
1. Finely stranded or solid copper conductor
2. PVC Insulation
3. PVC Outer sheath


TECHNICAL DATA :
Max. Operation Temperature : 70 C
Max. Short Circuit Temperature : 160 C
Rated Voltage (Uo/U) : 380V
AC Test Voltage : 2kV
NYIFY-F NYIFY-U
Harmonized Cables and Installation Cable
STANDARDS : TSE 9760 oHD 21.5 S3 oVDE 0281-5 oIEC 60227 oBS 6500


APPLICATION :
In dry, damp and wet locations as flexible connecting cables for light mechanical stresses. It's used at ambient
temperatures up to 70 ° C kitchen and hand tools etc.


CONSTRUCTION :
1. Finely stranded copper conductor
2. PVC Insulation
3. PVC Outer sheath


TECHNICAL DATA :
Max. Operation Temperature : 70 C
Max. Short Circuit Temperature : 160 C
Rated Voltage (Uo/U) : 300/300 V (H03VV-F)
300/500 V (H05VV-F)
AC Test Voltage : 2 kV

H03VV-F / H05VV-F (TTR)
Harmonized Cables and Installation Cables
STANDARDS : TSE 9760 - HD 21.5 S3 - VDE 0281-5 IEC 60227 -  BS 6500


APPLICATION :
Suitable in dry locations for connections of portable electrical appliances submitted to weak strength, like radio sets and lighting fittings but not for heating devices

CONSTRUCTION :
1. Finely stranded copper conductor
2. PVC Insulation


TECHNICAL DATA :
Max. Operation Temperature : 70C
Max. Short Circuit Temperature : 160C
Rated Voltage (Uo/U) : 300/ 300V (H03VH-H)
300/500 V (H05VH-H)
AC Test Voltage : 2 kV
H03VH -H , H05VH-H
Harmonized Cables and Installation Cable
STANDARDS : TSE 9760 oHD 21.5 S3 oVDE 0281-5 oIEC 60227 oBS 6500


APPLICATION :
In dry, damp and wet locations as flexible connecting cables for light mechanical stresses. It's used at ambient
temperatures up to 70 ° C kitchen and hand tools etc.


CONSTRUCTION :
1. Finely stranded copper conductor
2. PVC Insulation
3. PVC Outer sheath


TECHNICAL DATA :
Max. Operation Temperature : 70 C
Max. Short Circuit Temperature : 160 C
Rated Voltage (Uo/U) : 300/300 V (H03VV-F)
300/500 V (H05VV-F)
AC Test Voltage : 2 kV
H03V3V3-F / H05V3V3-F
Harmonized Cables and Installation Cables
STANDARDS : TS HD 21.12 S1 o VDE 0281 o BS 6141


APPLICATION :
For installations in domestic environment, kitchen, office and household appliances, also in humid conditions,
as well as connections subject to medium mechanical stress. Also, they can be used for kitchen or heating
appliances, if cable is not in direct touch with hot surfaces nor exposed to thermal irradiation.


CONSTRUCTION :
1. Finely stranded copper conductor
2. PVC Insulation
3. PVC Outer sheath


TECHNICAL DATA :
Max. Operation Temperature : 90 C
Max. Short Circuit Temperature : 160 C
Rated Voltage (Uo/U) : 300/300 V (H03V2V2-F)
300/500 V (H05V2V2-F)
AC Test Voltage : 2 kV
H03V2V2-F / H05V2V2-F
Harmonized Cables and Installation Cables
STANDARDS : TSE 9760 HD 21.5 S3 o VDE 0281 o IEC 60227 o BS 6500


APPLICATION :
Suitable in dry locations for connections of portable electrical appliances submitted to low voltage, like radio sets and lighting fittings but not for heating devices.


CONSTRUCTION :
1. Finely stranded copper conductor
2. PVC Insulation
3. PVC Outer sheath


TECHNICAL DATA :
Max. Operation Temperature : 70C
Max. Short Circuit Temperature : 160C
Rated Voltage (Uo/U) : 300/ 300V (H03VVH2-F)
300/500 V (H05VVH2-F)
AC Test Voltage : 2 kV
H03VVH2-F / H05VVH2-F
Harmonized Cables and Installation Cable
STANDARDS : TS HD 21.12 S1 o VDE 0281 o BS 6141


APPLICATION :
For installations in domestic environment, kitchen, office and household appliances, also in humid conditions,
as well as connections subject to medium mechanical stress. Also, they can be used for kitchen or heating
appliances, if cable is not in direct touch with hot surfaces nor exposed to thermal irradiation.


CONSTRUCTION :
1. Finely stranded copper conductor
2. PVC Insulation
3. PVC Outer sheath


TECHNICAL DATA :
Max. Operation Temperature : 90 C
Max. Short Circuit Temperature : 160 C
Rated Voltage (Uo/U) : 300/300 V (H03V2V2-F)
300/500 V (H05V2V2-F)
AC Test Voltage : 2 kV
H03V2V2H2-F / H05V2V2H2-F
Harmonized Cables and Installation Cables
STANDARDS : TS IEC 60502-1 VDE 0276 IEC 60502 BS 6346


APPLICATION :
Preferably for installation indoors, in cable ducts and in industrial plants or switching stations, underground installation with
additional protection where mechanical damage must be unexpected


CONSTRUCTION :
1. Solid or stranded copper conductor
2. PVC Insulation
3. Filler
4. PVC outer sheath


TECHNICAL DATA :
Max. Operation Temperature : 70 C
Max. Short Circuit Temperature : 160 C
Rated Voltage (Uo/U) : 0,6/1 kV
AC Test Voltage : 3,5 kV
CYKY
0,6/1 kV PVC Insulated Low Voltage Cables
STANDARDS :


APPLICATION :



CONSTRUCTION :
1. Solid or stranded copper conductor
2. PVC insulation
3. PVC Outer sheath


TECHNICAL DATA :
Max. Operation Temperature : 70 C
Max. Short Circuit Temperature : 250 C
Rated Voltage (Uo/U) : 0,6/1 kV
AC Test Voltage : 3,5 kV
CBT
0,6/ 1Kv PVC Insulated Low Voltage electric Cable
Zafer Kablo San Tic A.S.  Low Voltage Cable Manufacturer
Designed by Murat KOC
Copyright 2008 Zafer Kablo All Rights Reserved.
Clicky Web Analytics